Product Description
0.6/1KV PVC insulated armored cable is engineered for fixed installation in harsh environments, including underground burial, direct laying on the ground, and routing through tunnels or cable trenches.
Application
It is widely applied in power supply systems of industrial projects, mining facilities, and outdoor infrastructure where high mechanical protection and corrosion resistance are required.
Applicable Standard
IEC60228 IEC60502-1
Construction
- Conductor:Aluminum or Copper Conductor
- Insulation:PVC
- Bedding:PVC
- Armour:Steel Wire Armour
- Out Sheath: PVC
Technical Parameters
| Nom.Cross Section | Nom. Insulation Thickness | Steel Wire Armour Wire Dia | Nom.Sheath Thickness | Approx.Overall Diameter | Approx.Weight (KG/KM) | |
| mm2 | mm | mm | mm | mm | Cu | AL |
| 3X1.5 | 0.8 | 0.8 | 1.8 | 14.16 | 342 | – |
| 3X2.5 | 0.8 | 0.8 | 1.8 | 15.02 | 397 | 350 |
| 3X4 | 1 | 1.3 | 1.8 | 17.89 | 642 | 567 |
| 3X6 | 1 | 1.3 | 1.8 | 18.99 | 753 | 640 |
| 3X10 | 1 | 1.6 | 1.8 | 22.37 | 1103 | 914 |
| 3X16 | 1 | 1.6 | 1.8 | 24.63 | 1379 | 1080 |
| 3X25 | 1.2 | 1.6 | 1.8 | 24.3 | 1693 | 1217 |
| 3X35 | 1.2 | 1.6 | 1.8 | 26.1 | 2080 | 1420 |
| 3X50 | 1.4 | 1.6 | 1.9 | 29.2 | 2622 | 1729 |
| 3X70 | 1.4 | 2 | 2 | 33.1 | 3662 | 2347 |
| 3X95 | 1.6 | 2 | 2.2 | 37.4 | 4698 | 2906 |
| 3X120 | 1.6 | 2.5 | 2.3 | 41.2 | 5964 | 3704 |
| 3X150 | 1.8 | 2.5 | 2.4 | 44.7 | 7087 | 4298 |
| 3X185 | 2 | 2.5 | 2.5 | 48.8 | 8489 | 5000 |
| 3X240 | 2.2 | 2.5 | 2.7 | 54.2 | 10574 | 5988 |
| 3X300 | 2.4 | 2.5 | 2.9 | 59.3 | 12774 | 7021 |
| Nom.Cross Section | Nom. Insulation Thickness | Steel Wire Armour Wire Dia | Nom.Sheath Thickness | Approx.Overall Diameter | Approx.Weight (KG/KM) | |
| mm2 | mm | mm | mm | mm | Cu | AL |
| 4X4 | 1 | 1.25 | 1.8 | 18.8 | 728 | 628 |
| 4X6 | 1 | 1.25 | 1.8 | 20.03 | 858 | 708 |
| 4X10 | 1 | 1.6 | 1.8 | 23.84 | 1274 | 1023 |
| 4X16 | 1 | 1.6 | 1.8 | 26.38 | 1629 | 1235 |
| 4X25 | 1.2 | 1.6 | 1.9 | 27.8 | 2087 | 1453 |
| 4X35 | 1.2 | 1.6 | 2 | 30.2 | 2573 | 1694 |
| 4X50 | 1.4 | 1.6 | 2.1 | 33.7 | 3276 | 2085 |
| 4X70 | 1.4 | 2 | 2.3 | 38.3 | 4564 | 2811 |
| 4X95 | 1.6 | 2 | 2.4 | 43.2 | 5873 | 3485 |
| 4X120 | 1.6 | 2.5 | 2.6 | 47.8 | 7464 | 4451 |
| 4X150 | 1.8 | 2.5 | 2.7 | 51.8 | 8848 | 5131 |
| 4X185 | 2 | 2.5 | 2.9 | 56.9 | 10735 | 6083 |
| Nom.Cross Section | Nom. Insulation Thickness | Steel Wire Armour Wire Dia | Nom.Sheath Thickness | Approx.Overall Diameter | Approx.Weight (KG/KM) | |
| mm2 | mm | mm | mm | mm | Cu | AL |
| 5X1.5 | 0.8 | 1.25 | 1.8 | 16.69 | 568 | – |
| 5X2.5 | 0.8 | 1.25 | 1.8 | 17.77 | 657 | 578 |
| 5X4 | 1 | 1.25 | 1.8 | 20.12 | 848 | 723 |
| 5X6 | 1 | 1.6 | 1.8 | 22.19 | 1128 | 940 |
| 5X10 | 1 | 1.6 | 1.8 | 25.68 | 1498 | 1183 |
| 5X16 | 1 | 1.6 | 1.9 | 28.71 | 1949 | 1450 |
| 5X25 | 1.2 | 1.6 | 1.9 | 29.6 | 3881 | 3088 |
| 5X35 | 1.2 | 2 | 2 | 33.6 | 4644 | 3545 |
| 5X50 | 1.4 | 2 | 2.2 | 38.6 | 5980 | 4491 |
| 5X70 | 1.4 | 2 | 2.3 | 43.1 | 7668 | 5477 |
| 5X95 | 1.6 | 2.5 | 2.6 | 50.1 | 9806 | 6820 |
| 5X120 | 1.6 | 2.5 | 2.7 | 54.1 | 11501 | 7735 |
| 5X150 | 1.8 | 2.5 | 2.9 | 59.4 | 13780 | 9133 |
| 5X185 | 2 | 2.5 | 3.1 | 64.9 | 16562 | 10748 |
| 5X240 | 2.2 | 3.15 | 3.3 | 73.6 | 20662 | 13019 |
| 5X300 | 2.4 | 3.15 | 3.6 | 80.7 | 25004 | 15416 |