PVC Covered Conductors to BS6485

PVC Covered Conductors are designed for various overhead power line infrastructures. AMG Cable provides two core types:Type 8 and Type 16 to meet different voltage requirements.

BS 6485
BS 215-1
BS 215-2

Product Description

PVC Covered Conductors are designed for various overhead power line infrastructures. AMG Cable provides two core types:Type 8 and Type 16 to meet different voltage requirements.

Application

Type 8 suits systems where line-to-line voltage ≤ 650V RMS or conductor-to-earth voltage ≤ 250V RMS.

Type 16 is ideal for higher-voltage needs: line-to-line voltage > 650V RMS or conductor-to-earth voltage > 250V RMS. Typically used in systems with line-to-line voltage ≤ 11kV RMS or conductor-to-earth voltage ≤ 6.6kV RMS.

Applicable Standard

BS 6485 for PVC-Covered Conductors For Overhead Power Lines

BS 215-1 for Aluminum Stranded Conductors

BS 215-2 for Aluminum Conductors, Steel-Reinforced

BS 3242 for Aluminum Alloy Stranded Conductors used in overhead power transmission

BS 7884 for Copper and Copper-Cadmium Stranded Conductors intended for overhead electric traction and power transmission systems

Technical Parameters

PVC Covered Conductor (AAC/PVC) to BS 6485,BS 251-1
PVC Covered Conductor (ACSR/PVC) to BS 6485,BS 215-2
PVC Covered Conductor(CU/PVC) BS 6485,BS 7884
PVC Covered Conductor(COPPER-ALLOY/PVC) BS 6485,BS 7884
PVC Covered Conductor BS 6485,BS 3242 AAAC/PVC
Code
Word
Nominal
Cross-
Sectional
Area
Stranding and
Wire
Diameter
Approx.
Dia of Conductor
Max .DC Resistance at 20℃ Approx.
Breaking Load
Approximate Overall
Diameter of Covered
Conductor
Type 8
Approx. Weight
Type8
  mm2 mm Mm Ω/KM kN mm kg/km
Midge 22 7/2.06 6.18 1.227 3.99 8.2 100
Aphis 25 3/3.35 7.2 1.081 4.11 9.2 133
Gnat 25 7/2.21 6.63 1.066 4.59 8.8 118
Weevil 30 3/3.66 7.9 0.9082 4.86 10.1 158
Mosquito 35 7/2.59 7.77 0.7762 6.03 10.0 156
Ladybird 40 7/2.79 8.37 0.6689 6.87 10.6 177
Ant 50 7/3.10 9.30 0.5419 8.28 11.7 200
Fly 60 7/3.40 10.2 0.4505 9.90 12.4 249
Bluebottle 70 7/3.66 11.0 0.3881 11.34 13.2 285
Earwing 75 7/3.78 11.3 0.3644 11.94 13.6 302
Grasshopper 80 7/3.91 11.7 0.3406 12.78 13.9 319
Clegg 90 7/4.17 12.5 0.2994 14.53 14.7 359
Wasp 100 7/4.39 13.17 0.2702 16.00 16.0 360
Beetle 100 19/2.67 13.4 0.2704 17.42 15.6 387
Bee 125 7/4.90 14.7 0.2169 19.94 16.9 482
Cricket 150 7/5.36 16.1 0.1813 23.85 18.3 567
Hornet 150 19/3.25 16.3 0.1825 27.70 18.5 538
Caterpillar 175 19/3.53 17.7 0.1547 28.63 19.9 646
Chafer 200 19/3.78 18.9 0.1349 32.40 21.7 690
Spider 225 19/3.99 20.0 0.1211 36.01 22.2 809
Cockroach 250 19/4.22 21.1 0.1083 40.40 23.3 900
Butterfly 300 19/4.65 23.3 0.08916 48.70 25.5 1082
Moth 350 19/5.00 25.0 0.07711 56.37 27.2 1241
Drone 350 37/3.58 25.1 0.07741 57.45 27.3 1222
Locust 400 19/5.36 26.8 0.0671 64.73 29.0 1416
Centipede 400 37/3.78 26.5 0.06944 63.10 28.7 1353
Maybug 450 37/4.09 28.6 0.05931 74.01 30.8 1573
Scorpion 500 37/4.27 29.9 0.05441 79.98 32.1 1706
Cicada 600 37/4.65 32.6 0.04588 94.95 34.8 2010
Tarantula 750 37/5.23 36.6 0.03627 120.10 38.8 2519
Code
Word
Nominal
Cross-
Sectional
Area
Stranding&
Wire
Diameter
Approx.
Dia of Conductor
Max .DC Resistance at 20℃ Approx.
Breaking Load
Approximate Overall
Diameter of Covered
Conductor
Type 8
Approx. Weight
Type16
  mm2 mm Mm Ω/KM kN mm kg/km
25 6/2.36 1/2.36 7.08 1.093 9.61 10.7 190
50 6/3.35 1/3.35 10.05 0.5426 18.35 14.1 330
100 6/4.72 7/1.57 14.15 0.2733 32.70 18.2 550
150 30/2.59 7/2.59 18.13 0.1828 69.20 22.2 920
150 18/3.35 1/3.35 16.75 0.1815 35.70 20.8 680
175 30/2.79 7/2.79 19.53 0.1576 79.80 23.6 1050
175 18/3.61 1/3.61 18.05 0.1563 41.10 22.1 780
200 30/3.00 7/3.00 21.00 0.1363 92.25 25.0 1190
200 18/3.86 1/3.86 19.30 0.1367 46.55 23.3 870
Nominal cross-
sectional area
(mm²)
Stranding &
Wire Diameter
(mm)
Approx. Dia of Conductor Max. DC Resistance at 20℃ Approx. Breaking Load Approx. Dia Approx. Weight
Type 8 Type 16 Type 8 Type 16
  mm2 mm Ω/KM KN mm mm kg/km kg/km
14 7/1.60 4.80 1.303 5.744 6.8 8.4 160 190
16 3/2.65 5.70 1.106 6.590 7.7 9.3 180 220
32 3/3.75 8.06 0.5520 12.71 10.5 12.1 350 390
35 7/2.50 7.50 0.5337 14.097 9.9 11.5 360 400
70 7/3.55 10.65 0.2646 26.88 13.5 14.7 690 750
100 7/4.30 12.90 0.1810 37.64 15.7 16.9 990 1060
Nominal cross-
sectional area
Stranding &
Wire Diameter
Approx. Dia of Conductor Max. DC Resistance at 20℃ Approx. Breaking Load Approx. Dia

Type 16

Approx. Weight

Type 16

mm2 mm mm Ω/KM KN mm KG/KM
12 3/2.30 4.95 1.780 7.20 8.2 170
22 7/2.00 6.00 1.011 12.94 9.6 270
38 7/2.60 7.80 0.5983 21.69 11.8 430
75 7/3.70 11.10 0.2954 40.23 15.1 810
125 19/2.90 14.50 0.1784 68.75 18.5 1310
150 19/3.20 16.00 0.1465 82.16 20.0 1570
Nominal cross-
sectional area
Stranding &
Wire Diameter
Approx. Dia of Conductor Max. DC Resistance at 20℃ Approx. Breaking Load Approx. Dia

Type16yp

Approx. Weight

Type16Type 16

mm2 mm mm Ω/KM KN m KG/KM
25 7/2.34 7.02 1.094 8.44 10.6 170
50 7/3.30 9.90 0.5498 16.80 13.9 280
100 7/4.65 13.95 0.2769 33.30 18.0 470
150 19/3.48 17.40 0.1830 50.65 21.4 680
200 19/3.76 18.80 0.1568 59.10 22.8 780




      Related Products

      Wire and Cables Samples Available

      We work with clients to identify their exact application needs and technical specifications, enabling our
      technical team to provide tailored samples that meet all performance requirements.

      Have Questions?
      Get in Touch with Us.

      +86 188 3803 6118
      High-Tech Industrial Development Zone,Zhengzhou City,Henan Province,China

      Send Us a Message






        Your trusted partner in high- performance wire and cables