SIP Cable GOST 31946

SIP cable (Self-supporting Isolated and Projected Cable), is a special cable commonly used in overhead power lines

Design as per GOST 31946

Product Description

SIP cable (Self-supporting Isolated and Projected Cable), is a special cable commonly used in overhead power lines, which can be independently installed without additional load-bearing brackets and is widely applied in power transmission and household power supply scenarios.

Application

Self-supporting isolated and projected cables provide 0.6/1 kV, 20 kV and 35 kV aerial power supply, suitable for temporary power at construction sites, service drops (power pole to service entrance), secondary cables (pole-to-pole) and street lighting.

This overhead cable features reinforced insulation, complying with IEC 61140 standard and its Class II requirements. It is non-flame-retardant by default, but can be customized to a flame-retardant version upon request.

The main sizes of SIP cables are SIP-1,SIP-2, SIP-3, SIP-4.

Applicable Standard

Design as per GOST 31946

Construction

1. Conductor:

Aluminium conductor, round stranded compressed (RM)

2. Insulation:

XLPE compound, UV resistant

Technical Parameters

SIP-1 0.6/1KV
SIP-2 0.6/1KV
SIP-3 20 KV
SIP-4 0.6/1KV
Number of Cores
Cross Section
Nominal thickness of
Phase insulation
Overall
Diameter
Weight Maximum Conductor
Resistance Ω/Km
– mm mm Kg/Km Phase
1×16+1×25 1.3 15 135 1.910
3×16+1×25 1.3 22 270 1.910
3×25+1×35 1.3 26 390 1.200
3×35+1×50 1.3 30 530 0.868
3×50+1×50 1.5 32 685 0.641
3×50+1×70 1.5 35 740 0.641
3×70+1×70 1.7 37 930 0.443
3×70+1×95 1.7 41 990 0.443
3×95+1×70 1.7 41 1190 0.320
3×95+1×95 1.7 43 1255 0.320
3×120+1×95 1.7 46 1480 0.253
3×150+1×95 1.7 48 1715 0.206
3×185+1×95 1.9 52 2330 0.164
3×240+1×95 1.9 56 2895 0.125
Number of Cores
Cross Section
Nominal thickness of
phase insulation
Overall
Diameter
Weight Maximum Conductor
Resistance Ω/Km
– mm mm Kg/Km Phase
3×16+1×25 1.3 24 308 1.910
3×16+1×54.6 1.3 28 427 1.910
3×25+1×35 1.3 27 424 1.200
3×25+1×35 1.3 30 512 1.200
3×25+1×54.6 1.3 31 571 1.200
3×35+1×50 1.3 32 606 0.868
3×35+1×54.6 1.3 34 727 0.868
3×50+1×50 1.5 35 762 0.641
3×50+1×54.6 1.5 36 798 0.641
3×50+1×70 1.5 39 973 0.641
3×70+1×70 1.7 40 1010 0.443
3×70+1×95 1.7 41 1087 0.443
3×95+1×70 1.7 43 1240 0.320
3×95+1×95 1.7 45 1319 0.320
3×120+1×95 1.7 48 1553 0.253
3×150+1×95 1.7 50 1787 0.206
3×185+1×95 1.9 55 2403 0.164
3×240+1×95 1.9 60 2968 0.125
 

Number of Cores
Cross Section
Nominal thickness of
phase insulation
Overall
Diameter
Weight Maximum Conductor
Resistance
– mm mm Kg/Km Ω/Km
1×35 2.3 12 165 0.986
1×50 2.3 13 215 0.720
1×70 2.3 15 282 0.630
1×95 2.3 16 364 0.363
1×120 2.3 18 445 0.288
1×150 2.3 19 540 0.236
1×185 2.3 21 722 0.188
1×240 2.3 24 950 0.145
Number of Cores
Cross Section
Nominal thickness of
phase insulation
Overall
Diameter
Weight Maximum Conductor
Resistance Ω/Km
– mm mm Kg/Km Phase
2×16 1.3 15 139 1.910
4×16 1.3 18 278 1.910
2×25 1.3 17 196 1.200
4×25 1.3 21 392 1.200




      Related Products

      Wire and Cables Samples Available

      We work with clients to identify their exact application needs and technical specifications, enabling our
      technical team to provide tailored samples that meet all performance requirements.

      Have Questions?
      Get in Touch with Us.

      +86 188 3803 6118
      High-Tech Industrial Development Zone,Zhengzhou City,Henan Province,China