Product Description
SIP cable (Self-supporting Isolated and Projected Cable), is a special cable commonly used in overhead power lines, which can be independently installed without additional load-bearing brackets and is widely applied in power transmission and household power supply scenarios.
Application
Self-supporting isolated and projected cables provide 0.6/1 kV, 20 kV and 35 kV aerial power supply, suitable for temporary power at construction sites, service drops (power pole to service entrance), secondary cables (pole-to-pole) and street lighting.
This overhead cable features reinforced insulation, complying with IEC 61140 standard and its Class II requirements. It is non-flame-retardant by default, but can be customized to a flame-retardant version upon request.
The main sizes of SIP cables are SIP-1,SIP-2, SIP-3, SIP-4.
Applicable Standard
Design as per GOST 31946
Construction
1. Conductor:
Aluminium conductor, round stranded compressed (RM)
2. Insulation:
XLPE compound, UV resistant

Technical Parameters
| Number of Cores Cross Section |
Nominal thickness of Phase insulation |
Overall Diameter |
Weight | Maximum Conductor Resistance Ω/Km |
| – | mm | mm | Kg/Km | Phase |
| 1×16+1×25 | 1.3 | 15 | 135 | 1.910 |
| 3×16+1×25 | 1.3 | 22 | 270 | 1.910 |
| 3×25+1×35 | 1.3 | 26 | 390 | 1.200 |
| 3×35+1×50 | 1.3 | 30 | 530 | 0.868 |
| 3×50+1×50 | 1.5 | 32 | 685 | 0.641 |
| 3×50+1×70 | 1.5 | 35 | 740 | 0.641 |
| 3×70+1×70 | 1.7 | 37 | 930 | 0.443 |
| 3×70+1×95 | 1.7 | 41 | 990 | 0.443 |
| 3×95+1×70 | 1.7 | 41 | 1190 | 0.320 |
| 3×95+1×95 | 1.7 | 43 | 1255 | 0.320 |
| 3×120+1×95 | 1.7 | 46 | 1480 | 0.253 |
| 3×150+1×95 | 1.7 | 48 | 1715 | 0.206 |
| 3×185+1×95 | 1.9 | 52 | 2330 | 0.164 |
| 3×240+1×95 | 1.9 | 56 | 2895 | 0.125 |
| Number of Cores Cross Section |
Nominal thickness of phase insulation |
Overall Diameter |
Weight | Maximum Conductor Resistance Ω/Km |
| – | mm | mm | Kg/Km | Phase |
| 3×16+1×25 | 1.3 | 24 | 308 | 1.910 |
| 3×16+1×54.6 | 1.3 | 28 | 427 | 1.910 |
| 3×25+1×35 | 1.3 | 27 | 424 | 1.200 |
| 3×25+1×35 | 1.3 | 30 | 512 | 1.200 |
| 3×25+1×54.6 | 1.3 | 31 | 571 | 1.200 |
| 3×35+1×50 | 1.3 | 32 | 606 | 0.868 |
| 3×35+1×54.6 | 1.3 | 34 | 727 | 0.868 |
| 3×50+1×50 | 1.5 | 35 | 762 | 0.641 |
| 3×50+1×54.6 | 1.5 | 36 | 798 | 0.641 |
| 3×50+1×70 | 1.5 | 39 | 973 | 0.641 |
| 3×70+1×70 | 1.7 | 40 | 1010 | 0.443 |
| 3×70+1×95 | 1.7 | 41 | 1087 | 0.443 |
| 3×95+1×70 | 1.7 | 43 | 1240 | 0.320 |
| 3×95+1×95 | 1.7 | 45 | 1319 | 0.320 |
| 3×120+1×95 | 1.7 | 48 | 1553 | 0.253 |
| 3×150+1×95 | 1.7 | 50 | 1787 | 0.206 |
| 3×185+1×95 | 1.9 | 55 | 2403 | 0.164 |
| 3×240+1×95 | 1.9 | 60 | 2968 | 0.125 |
| Number of Cores Cross Section |
Nominal thickness of phase insulation |
Overall Diameter |
Weight | Maximum Conductor Resistance |
| – | mm | mm | Kg/Km | Ω/Km |
| 1×35 | 2.3 | 12 | 165 | 0.986 |
| 1×50 | 2.3 | 13 | 215 | 0.720 |
| 1×70 | 2.3 | 15 | 282 | 0.630 |
| 1×95 | 2.3 | 16 | 364 | 0.363 |
| 1×120 | 2.3 | 18 | 445 | 0.288 |
| 1×150 | 2.3 | 19 | 540 | 0.236 |
| 1×185 | 2.3 | 21 | 722 | 0.188 |
| 1×240 | 2.3 | 24 | 950 | 0.145 |
| Number of Cores Cross Section |
Nominal thickness of phase insulation |
Overall Diameter |
Weight | Maximum Conductor Resistance Ω/Km |
| – | mm | mm | Kg/Km | Phase |
| 2×16 | 1.3 | 15 | 139 | 1.910 |
| 4×16 | 1.3 | 18 | 278 | 1.910 |
| 2×25 | 1.3 | 17 | 196 | 1.200 |
| 4×25 | 1.3 | 21 | 392 | 1.200 |