0.6/1kV NYRY/NAYRY SWA Armored Cable

NYRY/NAYRY Armored Cable 0.6/1kV is applicable to a wide range of working environments, including indoor workshops, outdoor open-air sites, and underground facilities.

IEC 60502-1
ISIRI 3569-1

Product Description

NYRY/NAYRY Armored Cable 0.6/1kV is applicable to a wide range of working environments, including indoor workshops, outdoor open-air sites, and underground facilities.

Application

It is particularly recommended for use in areas that demand strict mechanical protection—such as heavy industrial plants, construction sites, and underground pipeline corridors—where the risk of mechanical wear, external force damage, or equipment collision is relatively high. This versatile adaptability allows the product to meet the operational needs of different projects while minimizing maintenance costs caused by mechanical failures.

Applicable Standard

IEC 60502-1   ISIRI 3569-1

Construction

  • 1. Conductor:Aluminum or Copper Conductor(Class 1 or Class2)
  • 2. Insulation: PVC
  • 3.Armour: Steel Wire Armour or Aluminum Wire Armour
  • 4. Sheath:PVC (Polyvinyl Chloride)(LSZH is available on request)
0.6/1kV NYRY/NAYRY SWA Armored Cable

Technical Parameters

1Core
2Core
3Core
4 Core
5 Core
3+1 Core
Nom.Cross Section No.&Dia of Wire Wire  Armor Size Nom. Insulation  Thickness Nom.Sheath Thickness Overall Diameter Approx.Weight(KG/KM)
mm2 mm mm mm mm mm CU Al
1×16 7×1.72 0.9 0.7 1.8 14.2 370 290
1×25 7×2.14 1.25 0.9 1.8 15.5 530 364
1×35 7×2.52 1.25 0.9 1.8 17.2 590 422
1×50 19×1.78 1.25 1 1.8 18.5 780 543
1×70 19×2.14 1.6 1.1 1.8 20.4 950 652
1×95 19×2.52 1.6 1.1 1.8 22.8 1220 965
1×120 37×2.03 1.6 1.2 1.8 24.4 1450 1105
1×150 37×2.25 1.6 1.4 1.8 26.3 1880 1288
1×185 37×2.52 1.6 1.6 1.9 28.6 2260 1585
1×240 61×2.25 2 1.7 2 31.4 2850 2070
1×300 61×2.52 2 1.8 2.1 34.6 3600 2520
1×400 61×2.85 2 2 2.2 37.8 4480 3100
1×500 61×3.24 2 2.2 2.3 41.9 5570 3840
Nom.Cross Section No.&Dia of Wire Wire  Armor Size Nom. Insulation  Thickness Nom.Sheath Thickness Overall Diameter Approx.Weight (KG/KM)
mm2 mm mm mm mm mm CU Al
2×1.5 1×1.38 0.9 0.7 1.8 13.3 245 —
2×2.5 1×1.78 0.9 0.7 1.8 14.3 310 —
2×4 1×2.25 1.25 0.7 1.8 15.8 415 —
2×6 1×2.78 1.25 0.7 1.8 17.5 500 —
2×10 1×3.57 1.25 0.7 1.8 19.4 790 750
2×16 7×1.72 1.25 0.7 1.8 21.2 910 900
2×25 7×2.14 1.6 0.9 1.8 24.5 1100 1340
2×35 7×2.52 1.6 0.9 1.8 26.8 1460 1548
2×50 19×1.78 2 1 1.9 29.5 1850 1940
2×70 19×2.14 2 1.1 2.1 34.5 2400 2600
2×95 19×2.52 2 1.1 2.2 38 3200 3320
2×120 37×2.03 2.5 1.2 2.3 41.5 3900 3900
2×150 37×2.25 2.5 1.4 2.5 46.3 5100 4910
2×185 37×2.52 2.5 1.6 2.6 51.9 6490 5995
2×240 61×2.25 2.5 1.7 2.7 58.2 8060 7350
Nom.Cross Section No.&Dia of Wire Wire  Armor Size Nom. Insulation  Thickness Nom.Sheath Thickness Overall Diameter Approx.Weight(KG/KM)
mm2 mm mm mm mm mm CU Al
3×1.5 1×1.38 0.9 0.7 1.8 13.8 330 —
3×2.5 1×1.78 0.9 0.7 1.8 14.7 390 —
3×4 1×2.25 1.25 0.7 1.8 17 530 —
3×6 1×2.78 1.25 0.7 1.8 18.1 700 —
3×10 1×3.57 1.25 0.7 1.8 20.2 800 820
3×16 7×1.72 1.6 0.7 1.8 22.7 980 1000
3×25 7×2.14 1.6 0.9 1.8 25.9 1510 1460
3×35 7×2.52 1.6 0.9 1.8 28 1850 1705
3×50 SM 19×1.78 1.6 1 1.9 28.9 2210 1800
3×70 SM 19×2.14 2 1.1 2 32.1 3110 2450
3×95 SM 19×2.52 2 1.1 2.1 36.8 4100 2950
3×120 SM 37×2.03 2 1.2 2.2 40.1 5120 3400
3×150 SM 37×2.25 2 1.4 2.4 44.8 6600 4500
3×185 SM 37×2.52 2.5 1.6 2.5 48.3 7950 5100
3×240 SM 61×2.25 2.5 1.7 2.7 53.5 9950 6200
Nom.Cross Section No.&Dia of Wire Wire  Armor Size Nom. Insulation  Thickness Nom.Sheath Thickness Overall Diameter Approx.Weight(KG/KM)
mm2 mm mm mm mm mm CU Al
4×1.5 1×1.38 0.9 0.7 1.8 14.6 370 —
4×2.5 1×1.78 1.25 0.7 1.8 15.5 435 —
4×4 1×2.25 1.25 0.7 1.8 17.6 540 —
4×6 1×2.78 1.25 0.7 1.8 19.1 665 —
4×10 1×3.57 1.6 0.7 1.8 22.3 870 920
4×16 7×1.72 1.6 0.7 1.8 24 1380 1100
4×25 7×2.14 1.6 0.9 1.8 27.6 1890 1580
4×35 7×2.52 2 0.9 1.9 30.3 2310 1920
4×50 SM 18×2.0 2 1 2 32 2780 2380
4×70 SM 18×2.38 2 1.1 2.1 36.3 4240 2830
4×95 SM 19×2.68 2 1.1 2.2 42 5380 3750
4×120 SM 37×2.19 2.5 1.2 2.4 46 6805 5120
4×150 SM 37×2.42 2.5 1.4 2.5 49.6 7760 5300
4×185 SM 37×2.68 2.5 1.6 2.7 57 9665 6200
4×240 SM 37×3.05 2.5 1.7 2.9 63.5 11270 7485
Nom.Cross Section No.&Dia of Wire Wire  Armor Size Nom. Insulation  Thickness Nom.Sheath Thickness Overall Diameter Approx.Weight(KG/KM)
mm2 mm mm mm mm mm CU Al
5×1.5 1×1.38 1.25 0.7 1.8 15.4 400 —
5×2.5 1×1.78 1.25 0.7 1.8 16.3 520 —
5×4 1×2.25 1.25 0.7 1.8 19 710 —
5×6 1×2.78 1.6 0.7 1.8 21 820 —
5×10 1×3.57 1.6 0.7 1.8 23.1 1230 1050
5×16 7×1.72 1.6 0.7 1.8 25.3 1615 1350
5×25 7×2.14 2 0.9 1.9 29.3 2130 1800
5×35 7×2.52 2 0.9 2 30.2 2930 2450
Nom.Cross Section No.&Dia of Wire Wire  Armor Size Nom. Insulation  Thickness Nom.Sheath Thickness Overall Diameter Approx.Weight(KG/KM)
mm2 mm mm mm mm mm CU Al
3×25/16 7×2.14/7×1.72 1.6 0.9/0.7 1.8 27.6 1800 1620
3×35/16 7×2.52/7×1.72 1.6 0.9/0.7 1.9 30.4 2190 1800
3×50/25 SM 18×2/7×2.14 2 1/0.9 1.9 29 2650 2030
3×70/35 SM 18×2.38/7×2.52 2 1.1/0.9 2.1 35 3720 2550
3×95/50 SM 19×2.68/18×2 2 1.1/1 2.2 37.5 4750 3170
3×120/70 SM 37×2.16/18×2.38 2 1.2/1.1 2.4 44 5935 4020
3×150/70 SM 37×2.42/18×2.38 2.5 1.4/1.1 2.5 46.5 7460 4860
3×185/95 SM 37×2.68/19×2.68 2.5 1.6/1.1 2.6 49.3 8845 5650
3×240/120 SM 37×3.05/37×2.16 2.5 1.7/1.2 2.8 56 11255 6910




      Related Products

      Wire and Cables Samples Available

      We work with clients to identify their exact application needs and technical specifications, enabling our
      technical team to provide tailored samples that meet all performance requirements.

      Have Questions?
      Get in Touch with Us.

      +86 188 3803 6118
      High-Tech Industrial Development Zone,Zhengzhou City,Henan Province,China

      Send Us a Message






        Your trusted partner in high- performance wire and cables